MCR Safety details the updates to the ANSI/ISEA 105 PPE marking update which addresses the classification and testing of hand protection related to chemical and industrial applications.

8.2 Specific Marking

Hand and arm protection shall be marked per the pictogram here. Markings shall be affixed so as to be visible and legible throughout the normal useful life of the glove. The following convention shall be applied, where applicable classifications are claimed by the manufacturer:

a. Cut-resistance, Section 6.1.1 (inside center)
b. Abrasion resistance, Section 6.1.4 (inside left)
c. Puncture resistance, non-hypodermic needle, Section 6.1.2 (inside right).

6.1.1 Cut Resistance

When tested in accordance with ASTM F2992-15, the glove’s or sleeve’s cut resistance shall be classified against the levels listed in Table 1, using the weight needed to cut through the material with 20 mm of blade travel. Data collection procedures in Appendix A shall be followed. Calculation for cut resistance classification may be done using the ISEA standardized template available at www.safetyequipment.org. The average of a minimum of 3 samples shall be used to report the classification level.

Expand
Expand

6.1.4 Abrasion Resistance

When tested in accordance with ASTM D3389-16, or ASTM D3884-09 (2017), the glove or sleeve’s abrasion resistance shall be classified against the levels listed in Table 4 using the number of abrasion cycles to failure (test endpoint).

These test methods shall be followed using H-18 abrasion wheels with a 500 gram load for levels 0 to 3. If the samples exceed 1000 revolutions at the 500 gram load, new (untested) samples shall be used to determine levels 4 to 6 using 1000 gram load.

NOTE: It is not the intention to apply the 1000 gram load to the same sample to continue the test.

Using ASTM D3389-16 for coated glove materials or unsupported gloves, the end point at which the glove or sleeve material is determined to fail shall be at the number of abrasion cycles until the film or coating is worn through the glove or sleeve’s coating and liner. Using ASTM D3884-09 (2017) for uncoated glove or sleeve materials, the end point at which the glove or sleeve material is determined to fail shall be at the number of abrasion cycles needed to wear through the specimen.

The average of a minimum of 5 specimens shall be used to report the classification level.

6.1.2 Puncture Resistance (other than Hypodermic Needle)

When tested in accordance with clause 6.4 of EN 388:2016, the glove or sleeve’s resistance against puncture shall be classified against the levels listed in Table 2, using the puncture force.

The average of a minimum of 12 specimens shall be used to report the classification level.

Download a PDF of this update here.

Talk to Us!

Leave a reply

Your email address will not be published. Required fields are marked *

MCR Safety has over forty years of experience as a leader in the field of personal protective equipment (PPE). Our assortment of offerings includes gloves, glasses, and garments which are made from the highest quality materials available to ensure maximum safety, comfort, and style.

Browse Products from MCR Safety

More on Regulatory Compliance

The new ANSI standard for heat stress management mandates access to electrolyte replenishment beverages free of charge.

OSHA has addressed the hazards present in warehousing and distribution operations by launching the National Emphasis Program (NEP).

Read about the required supplies that must be included in first aid kits to comply with a new ANSI standard that went into effect October 15, 2022.

MSC

Signing into Better MRO is easy. Use your MSCdirect.com username / password, or register to create an account. We’ll bring you back here as soon as you’re done.

Redirecting you in 5 seconds